Description: Refrigerant Digital Manifold Gauge Set Home 3 Way HVAC Pressure AC Recharge Kit Connecting with the System NOTE: Before connecting to the system, please check whether the pressure gauge pointer is in the zero position, otherwise open the table adjusting the screw to the zero position. First close the low pressure valve, high pressure valve; After interface connecting with blue tube(Iow voltage fast connector), and then locking to system low pressure; After interface connecting with the red tube(low voltage fast connector), and then locking to the system high pressure. interface connecting with yellow tube and vacuum pump. Vacuum Pumping System NOTE: this step must be carried out under the system pressure, otherwise it should be advanced relief pressure. Upon completing the above, then open the vacuum pump; Open low pressure valve(blue),high pressure valve(red),and (open the high and) low pressure fast interface)the system begins to draw a vacuum; After a certain period of time(10-30min), check whether the system is completely vacuum, otherwise the vacuum should be repaired and re evacuation; Close the high and low pressure valves at the same time, and close the vacuum pump eventually. System Filling Refrigerant Put away the yellow tube and vacuum pump, and then the refrigerant bottle was tightened. Open the refrigerator bottle(forward), and valve core on the table group, exhaust yellow pipe in the air; Invert the refrigerant bottle, open low pressure valve, high pressure valve to add refrigerant; To the specified amount(according to the system provided by the manufacturer of the volume), close the high pressure valve, low pressure valve, while positive refrigerant bottle; After run the system test(about 5-10min), check the system pressure and temperature; If the refrigerant is insufficient, positive the refrigerant bottle, and open the low pressure valve slowly(it is prohibited to open high pressure valve), putting the proper amount of refrigerant gas; If it is too high, you should turn off the cylinder, open the high pressure valve slowly, discharge the amount of refrigerant(at this point should pay attention to the discharge of refrigerant wounding)from table group core, and close the high pressure valve, and retest.back and forth until normal; After running normally, close the refrigerant bottle and valve and then put high and low voltage fast connection and system(pay attention to high temperature hot)away. Use and Maintenance 1.Detect the high pressure valve, low pressure valve, prohibit misuse to prevent damage to the pressure gauge; 2.Do not use the working quality which is not consistent with the table group; 3.Cannot be forced too much closing the high and low pressure valve; 4.After use release the valve, proper storage, anti shock and fall; 5.Please read the instruction in detail or operate under the guidance of professionals. PaymentDelivery detailsTerms of salesAbout usContact usPaymentWe only accept PayPal payments.Payment should be made within 5 days after bidding ends.We are not responsible for buyers' local taxes.(1) Import duties, taxes and charges are not included in the item price or shipping charges. These charges are the buyer responsibility.(2)Please check with your country customs office to determine what these additional costs will be prior to bidding / buying.Delivery detailsWe only ship parcel to the address in eBay payment. (1)0Please make sure payment address in eBay is correct. (2)Please be known that different shipping service means different shipping charge and shipping time!!! (3)All packages will be added with a tracking number.Terms of sales(1)Item may be returned for refund or replacement within 30 days of the purchase date. Returned merchandise must be unused, in original packaging and include all accessories. Shipping costs are non-refundable.(2)Defective products may be returned for repair up to 1 year from the purchase date. Repairs will be processed through the manufacturer, we will assist in the repair procedure in any way we can to expedite the process.(3)Before any return, a Return Merchandise Authorization (RMA) must be obtained by contacting the seller. Any products returned to us without an RMA will be sent back to the buyer at his/her expense. The buyer is responsible for the cost of returning any merchandise.About us(1)We are a professional worldwide wholesale company, with own factory located in China. We supply many products on Automobile consumer . Also offer reasonable prices , excellent customer service and a reliable credit standing are our target!(2)We are a professional Authorized dealers of AUTOOL,Launch,Autel and Xtool .(3)Global logistics system:US warehouse, German warehouse, China warehouse.Contact us(1)Our normal business hour is Monday to Friday 9:00 AM to 6:00 PM Beijing TIME.(2)Please email me through "MY MESSAGES" on eBay, if you have any questions about our listings or inventory or troubles.(3)Welcome your any-time parchase!
Price: 76.99 USD
Location: Cranbury, New Jersey
End Time: 2023-08-21T08:18:36.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Autory
Type: Leak Detector
Refrigerant: R-12, R-1234yf, R-134a, R404A
Gauge Purpose: Pressure, Test, Vacuum
Vacuum Units: PSI
Color: Black
Gauge Fill: Dry
Items Included: Blue Low Side Hose, Red High Side Hose, Yellow Service Hose
Item Width: 6.6cm
Item Length: 17.7cm
Item Weight: 2.2kg
Manufacturer Warranty: 2 Years
Year Manufactured: 2023
Country/Region of Manufacture: China
Number of Valves: 3